The FDA approved a prescription tongue muscle stimulation device that claims to reduce mild sleep apnea and snoring in patients with obstructive sleep apnea.
The FDA recently announced the approval of a prescription tongue muscle stimulation device that claims to reduce mild obstructive sleep apnea (OSA) and snoring. The device, called eXciteOSA, is approved through the de novo regulatory pathway for people 18 years and older.
Compared with prior devices used at nighttime for the treatment of OSA, such as continuous positive airway pressure therapy, eXciteOSA would be the first device to improve tongue muscle function while awake, which over time can prevent the tongue from collapsing backward and obstructing the airway during sleep.
The approval comes after the FDA assessed the safety and effectiveness of the device in 115 patients with snoring, including 48 patients with comorbid snoring and mild sleep apnea. Each participant underwent eXciteOSA therapy for 20 minutes once a day for 6 weeks.
After being reassessed 2 weeks following therapy discontinuation, the percent of time spent snoring at levels louder than 40dB, the noise level at which snoring begins to impact sleep, was found to be reduced by more than 20% in three-fourths of the patient cohort (n = 87). Moreover, among patients with comorbid snoring and mild sleep apnea, average levels of the Apnea Hypopnea Index (AHI) fell by 48%, from 10.21 to 5.27, in 41 of the 48 patients.
“Obstructive sleep apnea not only impacts sleep quality, but can have other serious health impacts if untreated. Today’s authorization offers a new option for the thousands of individuals who experience snoring or mild sleep apnea,” said Malvina Eydelman, MD, director of the Office of Ophthalmic, Anesthesia, Respiratory, ENT and Dental Devices in the FDA’s Center for Devices and Radiological Health, in a statement.
Through a silicone mouthpiece with 4 electrodes distributed above and below the tongue, the device delivers electrical muscle stimulation in sessions that consist of a series of electrical pulses, with rest periods in between. Similar to the study, its recommended use is for 20 minutes once a day during a wakeful state for 6 weeks and once a week after initial therapy.
Notably, eXciteOSA is not intended for patients with diagnosed severe OSA, represented by AHI levels of 15 and higher. The device is also contraindicated for patients with pacemakers or implanted pacing leads, who are pregnant, who have ulcerations in or around the mouth, and who have various dental and orthodontic hardware, such as dental braces.
A comprehensive dental examination was additionally recommended prior to use of the device, with the most common adverse events including excessive salivation, tongue or tooth discomfort, tongue tingling, dental filling sensitivity, metallic taste, gagging, and tight jaw.
The FDA’s marketing authorization was granted to Signifier Medical Technologies, LLC, who manufactures eXciteOSA.
At EHA 2025, Hematology Discussions Will Stretch Across Lifespans and Locations
June 5th 2025The 2025 European Hematology Association (EHA) Congress, convening virtually and in Milan, Italy, from June 12 to June 15, 2025, will feature a revamped program structure for the meeting’s 30th anniversary while maintaining ample opportunities to network, debate, and absorb practice-changing findings in hematology and oncology.
Read More
Laundromats as a New Frontier in Community Health, Medicaid Outreach
May 29th 2025Lindsey Leininger, PhD, and Allister Chang, MPA, highlight the potential of laundromats as accessible, community-based settings to support Medicaid outreach, foster trust, and connect families with essential health and social services.
Listen
Workers Facing Greater Economic Hardship More Likely to Report Poor Health
June 2nd 2025US workers facing high economic hardship, especially those in lower-wage occupations, were significantly more likely to report fair or poor health, underscoring persistent disparities in worker well-being.
Read More